INFRARED MOISTURE ANALYZER (LI-IMB-79)
May 20, 2016
BACTERIOLOGICAL INCUBATORS (LI-BI-ADV)
May 21, 2016
Show all

BACTERIOLOGICAL INCUBATORS

CAPACITY

 

  • High-quality cold rolling steel electrostatic spraying exterior.
  • Stainless steel inner chamber, foursquare semicircle transition convenient for cleaning.
  • Adjustable shelves
  • Micro-computer intelligent control system with PID program. (Optional)
  • Large screen digital display and soft touch operation keys. (Optional)
  • Over temperature protection and auto-power break-off. (Optional)
  • Digital Timer (Optional)
  • Double door seal.

CAPACITY

These are sturdy double walled units with outer chamber made of M.S. sheet duly powder coated inner made up of anodised

alluminium or S.S. 304. The gap between inner and outer chamber is _filled with high grade glass wool to avoid thermal losses.

Beaded heating elements are placed in ribs, at bottom and sides. The door is  fitted with glass viewing window to facilitate

inspection of sample without disturbing the test Temp. Temperature is controlled by thermostat from ambient to 90°C

±0.5°C. Air ventilators are also provided on the sides of unit. To work on 220 / 230 volts A.C. supply.

CAPACITY

Bacteriological Incubators are double walled convection heated units. Outer body of our incubators are constructed out of thick PCRC sheet duly pre-treated with primers and rust proofing and painted with long lasting stove enamel or elegantly powder coated. The inner chamber is made of heavy gauge stainless steel sheet of S.S-304 grade. The gap between the walls is filled high grade mineral glass wool, which ensures maximum thermal efficiency in our bacteriological incubators. The unit is mounted on a sturdy steel frame and provided with castor wheels (Large Sized Models Only) for easy movement inside the laboratory. The unit is provided with one to three stainless steel shelves (As per the inner size).

CAPACITY

Indirect heating system is provided in our units, comprising of air heaters made of high grade Kanthal A-1 wires of suitable wattage. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring a very good temperature sensitivity.

CAPACITY

Temperature range of our standard bacteriological incubator models are 5°C above ambient to 90°C, However we have the capacity to modify the same to suit the individual specialized requirements of our customers. Temperature inside our bacteriological incubators are controlled with a sensitivity of + 0.5°C or better.

 

CAPACITY

Front panel of our units comprises of on/off switches heating and mains indicator lamps, temperature controllers/Thermostat.

CAPACITY

The temperature inside our bacteriological incubator is controlled either through thermostat (Sensitivity + 2°C) or through solid state or micro-processor based temperature controllers cum indicators.

CAPACITY

   

Temperature Control                                                                                         

 

Temperature Sensitivity                        ± 0C                                       0.5 or Better

Spatial Deviation Temperature          ± 0C                                       0.5 or Better

Readability                                                      0                                      0.1

Temperature Range                                    0                                      50C to 600C (Standard)

Temperature Sensor                                     –                                         PT-100

Temperature Controller                              –                                        Solid State Digital Controller/PID (Optional)

Display                                                                 –                                        LED/LCD

Adjustable alarm limits                                –                                       Optional With PID Controller Only.

 

   

Safety Thermostats                                                                                  

 

Temperature Variation Adjustment        –                                      3 (With PID Controllers Only)

Temperature Sensors                                      –                                     PT-100

Automatic Temperature Setting                 –                                     Yes (With PID Controllers Only)

Adjustable limits                                                –                                     Yes (With PID Controllers Only)         

 

   

Shelf                                                                         –                                    

 

Standard                                                                 –                                     1/2/3 (Size Specific)

 Internal Dimensions                                      mm                                  Model Specific

Maximum Permitted load per Shelves     kg                                   25 kg (As per chamber size)

Maximum permitted total load                   kg                                    75 kg

 

   

Power Consumption                                                                                 

 

Nominal Power                                                    W                                    6001250

Nominal Voltage                                                   V                                    220-230 Volts, 50 Hz Single Phase

Frequency                                                              Hz                                    50

 

CAPACITY

This is unique module which can be incorporated with our Bacteriological incubators to log in temperature and environment related data with a help of a data logger unit which has a pc connectivity by means of RS 232 C interface. This data is then analyzed and formatted with the help of our unique user friendly analysis software to enable the user to get a formatted and analyzed reports of various inputs during the full operation cycle of the equipment. This is an ideal module for pharmaceutical laboratories, process control applications and high research projects where maintaining a viable record of the performance of the equipment is very essential.

SPECIFICATIONS

Chamber Size(H×W×D)

Mm

          inches. No. of

Shelf

Capacity(approx.)

liters

A 300 ×300 × 300 (12”×12”×12”) 2 28
B 350 ×350 × 350 (14”×14”×14”) 2 45
C 400 × 400 × 400 (16”×16”×16”) 2 65
D 450 × 450 × 450 (18”×18”×18”) 2 95
E 600 × 450 × 450 (24”×18”×18”) 2 125
F 600 × 600 × 600 (24”×24”×24”) 2 224
G 900 ×600 × 450 (36”×24”×18”) 2 252
H 900 × 600 × 600 (36”×24”×24”) 2 336
I 900 × 900 × 900 (36”×36”×36”) 3 720