INFRARED MOISTURE ANALYZER (LI-IMB-79)
May 20, 2016BACTERIOLOGICAL INCUBATORS (LI-BI-ADV)
May 21, 2016
BACTERIOLOGICAL INCUBATORS
- High-quality cold rolling steel electrostatic spraying exterior.
- Stainless steel inner chamber, foursquare semicircle transition convenient for cleaning.
- Adjustable shelves
- Micro-computer intelligent control system with PID program. (Optional)
- Large screen digital display and soft touch operation keys. (Optional)
- Over temperature protection and auto-power break-off. (Optional)
- Digital Timer (Optional)
These are sturdy double walled units with outer chamber made of M.S. sheet duly powder coated inner made up of anodised
alluminium or S.S. 304. The gap between inner and outer chamber is _filled with high grade glass wool to avoid thermal losses.
Beaded heating elements are placed in ribs, at bottom and sides. The door is fitted with glass viewing window to facilitate
inspection of sample without disturbing the test Temp. Temperature is controlled by thermostat from ambient to 90°C
±0.5°C. Air ventilators are also provided on the sides of unit. To work on 220 / 230 volts A.C. supply.
Bacteriological Incubators are double walled convection heated units. Outer body of our incubators are constructed out of thick PCRC sheet duly pre-treated with primers and rust proofing and painted with long lasting stove enamel or elegantly powder coated. The inner chamber is made of heavy gauge stainless steel sheet of S.S-304 grade. The gap between the walls is filled high grade mineral glass wool, which ensures maximum thermal efficiency in our bacteriological incubators. The unit is mounted on a sturdy steel frame and provided with castor wheels (Large Sized Models Only) for easy movement inside the laboratory. The unit is provided with one to three stainless steel shelves (As per the inner size).
Indirect heating system is provided in our units, comprising of air heaters made of high grade Kanthal A-1 wires of suitable wattage. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring a very good temperature sensitivity.
Temperature range of our standard bacteriological incubator models are 5°C above ambient to 90°C, However we have the capacity to modify the same to suit the individual specialized requirements of our customers. Temperature inside our bacteriological incubators are controlled with a sensitivity of + 0.5°C or better.
Front panel of our units comprises of on/off switches heating and mains indicator lamps, temperature controllers/Thermostat.
The temperature inside our bacteriological incubator is controlled either through thermostat (Sensitivity + 2°C) or through solid state or micro-processor based temperature controllers cum indicators.
|
Temperature Control
Temperature Sensitivity ± 0C 0.5 or Better
Spatial Deviation Temperature ± 0C 0.5 or Better
Readability 0C 0.1
Temperature Range 0C 50C to 600C (Standard)
Temperature Sensor – PT-100
Temperature Controller – Solid State Digital Controller/PID (Optional)
Display – LED/LCD
Adjustable alarm limits – Optional With PID Controller Only.
|
|
Safety Thermostats
Temperature Variation Adjustment – 3 (With PID Controllers Only)
Temperature Sensors – PT-100
Automatic Temperature Setting – Yes (With PID Controllers Only)
Adjustable limits – Yes (With PID Controllers Only)
|
|
Shelf –
Standard – 1/2/3 (Size Specific)
Internal Dimensions mm Model Specific
Maximum Permitted load per Shelves kg 25 kg (As per chamber size)
Maximum permitted total load kg 75 kg
|
|
Power Consumption
Nominal Power W 600–1250
Nominal Voltage V 220-230 Volts, 50 Hz Single Phase
Frequency Hz 50
|
This is unique module which can be incorporated with our Bacteriological incubators to log in temperature and environment related data with a help of a data logger unit which has a pc connectivity by means of RS 232 C interface. This data is then analyzed and formatted with the help of our unique user friendly analysis software to enable the user to get a formatted and analyzed reports of various inputs during the full operation cycle of the equipment. This is an ideal module for pharmaceutical laboratories, process control applications and high research projects where maintaining a viable record of the performance of the equipment is very essential.
|
Chamber Size(H×W×D)
Mm |
inches. |
No. of
Shelf |
Capacity(approx.)
liters |
A |
300 ×300 × 300 |
(12”×12”×12”) |
2 |
28 |
B |
350 ×350 × 350 |
(14”×14”×14”) |
2 |
45 |
C |
400 × 400 × 400 |
(16”×16”×16”) |
2 |
65 |
D |
450 × 450 × 450 |
(18”×18”×18”) |
2 |
95 |
E |
600 × 450 × 450 |
(24”×18”×18”) |
2 |
125 |
F |
600 × 600 × 600 |
(24”×24”×24”) |
2 |
224 |
G |
900 ×600 × 450 |
(36”×24”×18”) |
2 |
252 |
H |
900 × 600 × 600 |
(36”×24”×24”) |
2 |
336 |
I |
900 × 900 × 900 |
(36”×36”×36”) |
3 |
720 |