Environmental Chamber (Stability Chamber) (LI-EC/S-C50)

CONSTANT TEMPERATURE REFRIGERATION-LIQUID BATH (COOLING BATH) (LI-CB-18)
May 23, 2016
Plant Growth Chamber (LI-PGC-51)
May 24, 2016
Show all

Environmental Chamber (Stability Chamber)

SPECIFICATIONS

  • Precise Control of Environmental Parameters
  • Micro-processor based Controllers
  • Aesthetically designed
  • Corrosion Resistant interior and exteriors
  • Energy Efficient
  • CFC free cooling
  • Sturdy Construction
  • Low Maintenance
  • Light Weight

 

CONSTRUCTION

Labard environmental chambers are double walled convection heated and cooled units. Outer body of our environmental chambers are constructed out of thick PCRC sheet duly pre-treated with primers and rust proofing and painted with long lasting stove enamel or elegantly powder coated.. The inner chamber is made of heavy gauge stainless steel sheet of SS-304 grade or anodized aluminum sheet or G.I. (as per the customer’s requirements). The gap between the walls is filled high grade mineral glass wool, which ensures maximum thermal efficiency in our walk in incubators

The unit is provided with two doors , the inner door is made of thick plexi glass/float glass, to view the specimens/culture media/stocks, without disturbing the temperature of the chamber. This door is provided with magnetic door closer. The outer door is made of mild steel sheet lined with stainless steel from inside.. This door is provided with lock and key arrangement. The unit is mounted on a sturdy steel frame The unit is provided with various customized shelves in various permutations and combinations to suit individual requirements.. The triple walled back of our environmental chambers are provided with two/Four/Six/Eight (size specific) air circulation fans for uniform maintenance of the temperature throughout the chamber.

 

HEATING

Indirect heating system is provided in our units, comprising of air heaters made of high grade Kanthal A-1 wires of suitable wattage.. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring a very good temperature sensitivity.

 

Cooling :

An energy efficient cooling unit is installed in our environmental chambers to enable bio chemical demand, cyclic and growth studies at lower room temperatures. We use ISI marked high end CFC free compressors conforming to latest international standards and guidelines.

 

Humidity :

Humidity generation provision is incorporated in our environmental chambers The humidity is generated by means of aerosol humidity generator with efficient humidity controller cum indicator.

 

Humidity Range :

From Ambient to 95% (As per the temperature Requirements)

 

Humidity Sensitivity :

Humidity is controlled by mean of an electronic humidity controller cum indicator with an accuracy of + 5.

ILLUMINATION

Our environmental chambers are provided with door operated illumination system comprising of fluorescent lights, beside two panels of diffused fluorescent light panel located at the either side of the chamber to enable the user to conduct the photo periodic tests and experiments.

 

Illumination Control :

The illumination is controlled through solid state cyclic timer to control the photoperiodic cycle of the chamber.

FORNT PANEL

Front panel of our units comprises of on/off switches heating, cooling and mains indicator lamps, temperature controllers and voltmeters.

 

TECHNICAL MATRIX

Temperature Control
Temperature Sensitivity ± 0C 0.5 or Better
Spatial Deviation in Temperature ± 0C 0.5 or Better
Readability 0C 0.1
Temperature Range 0C 50 C to 900 C
Temperature Sensor PT-100
Temperature Controller Solid State Digital Controller / PID Optional
Display

LED/LCD

 

Adjustable alarms limit Optional With PID Controller Only
Water Quality Distilled/Ionized
Safety Thermostats
Temperature Variation Adjustment 3 (With PID Controllers Only)
Temperature Sensors PT-100
Automatic Temperature Setting Yes (With PID Controllers Only)
Adjustable limits Yes (With PID Controllers Only)
Light Control
Readability or Set ability % 10% Optional Feature
Light Intensity (Middle Chamber) LUX As Desired (Optional Feature)
Light Intensity (Both Sides) LUX As Desired (Optional Feature)
Shelf
Standard 3
Internal Dimensions mm Model Specific
Maximum permitted load per shelf kg 25 kg
Maximum permitted total load kg 75 kg
Power Consumption
Nominal Power W 950
Nominal Voltage V 220-230 Volts, 50Hz Single Phase
Frequency Hz 50

Optional Upgrades

This is unique module which can be incorporated with our Environmental Chamber to log in temperature and environment related data with a help of a data logger unit which has a pc connectivity by means of RS 232 C interface. This data is then analyzed and formatted with the help of our unique user friendly analysis software to enable the user to get a formatted and analyzed reports of various inputs during the full operation cycle of the equipment. This is an ideal module for pharmaceutical laboratories, process control applications and high research projects where maintaining a viable record of the performance of the equipment is very essential.

SPECIFICATIONS

Size inside chamber (W × D × H ) Capacity (Approx.)
A 455 × 455 × 455 mm 95 liters
B 455 × 455 × 710 mm 147 liters
C 605 × 605 × 605 mm 225 liters
D 605 × 605 × 910 mm 335 liters

OPTIONAL

  1. Hygrometer (Humidity Indicator)
  2. Digital temp. controller-cum-indicator
  • Microprocessor PID digital temp. indicator-cum-controller
  1. Automatic electronic controller with digital display for temp. & humidity combined.
  2. Automatic voltage stabilizer 3 KVA (Recommended)